The GfS Exit Control 179/1125 secures the emergency exit and allows it to be opened with just one single handle.
In the locked position, the GfS Exit Control 179/1125 secures the door handle; the door can be used in an emergency with a single opening movement. By pressing down the door handle, the GfS Exit Control 179/1125 moves vertically downwards, freeing the handle. At the same time, a continuous signal sounds. The continuous alarm can only be deactivated and the door guard reset to its original position with the help of a key. For sustained passage operation, the permanent release of the system is possible via the device key. The door can also be used individually without triggering an alarm by using the key with the change function of the door lock. This means: The door can be opened with just one handle in case of danger, but the alarm signal alerts to unauthorized use.

The barrier under the door handle is active. In an emergency, the door can be opened with one handle.

When the door handle is pressed, the Exit Control 179/1125 automatically shifts downwards. Passing through the emergency exit door is now possible. A continuous alarm sounds, which can only be deactivated by an authorized person using the device key.

Authorized persons do not use the handle but open the latch with the key to enter the door without triggering the alarm.

With the device key, the door guard can be moved downwards into a permanent release position without triggering an alarm. In this position, the door can be used normally, e.g., for extended goods transport.

As soon as the door handle suppresses the pre-alarm, an alarm is triggered. The alarm ceases when the handle is released. However, if the user pushes the handle down completely, it irrevocably triggers the main alarm and the door guard releases the handle.

The basic functions of the EH Wireless Door Guard are the same as already described. It is used when the signal needs to be transmitted to an external alarm system, whether at the gatehouse, in the nurse's or janitor's office.

Skip product gallery

Direkt zum GFS EH-TÜRWÄCHTER®

GfS Exit Control 179/1125 Pre-alarm Battery Monitoring, RAL 6029
GFS EH-Exit Control The GfS Exit Control 179/1125 secures the emergency exit and allows it to be opened with just a single hand movement. In the locked position, the GfS Exit Control 179/1125 secures the door handle; the door can be accessed in an emergency with a single opening movement. By pressing down the door handle, the GfS Exit Control 179/1125 moves vertically downward and releases the handle. At the same time, a continuous signal sounds. The continuous alarm can only be deactivated with the help of a key, and the door guard can be reset to its original position. For continuous passage operation, the system's permanent release is possible using the device key. The door can also be accessed without triggering an alarm using the key through the change function of the door lock. This means: The door can be opened with just one hand movement in case of danger, but the alarm signal alerts to unauthorized use. The threshold under the door handle is active.In an emergency, the door can be openedwith a single hand movement. When the door handle is pressed down,the Exit Control 179/1125 automatically moves downward. Theemergency exit door can now be accessed. Acontinuous alarm sounds, which can only be deactivatedby an authorized person using the device key. Authorized persons do not use the handle,but open the lock latch with the key,to access the door without triggering an alarm. With the device key, the door guard can bemoved downward into apermanent release position without triggering an alarm. In thisposition, the door can be accessed normally, e.g., for a longer goods transport. As soon as the door handle triggers the pre-alarm,an alarm is triggered. Releasing the handlesilences the alarm. However, if the userpresses the handle all the way down, itirreversibly triggers the main alarm and thedoor guard releases the handle. The basic functions of the EH wirelessdoor guard are the same as already described.It is used when the signal needs to be forwarded to an externalalarm system, whether at theporter's lodge, in the nurse's station, or the janitor's office.
Show details
Prod.-Nr.: 990100 BUE
€710.91*
GfS Exit Control 179/1125 with pre-alarm, RAL 6029
GFS Exit Control The GfS Exit Control 179/1125 secures the emergency exit and allows it to be opened with just one single motion. In the locked position, the GfS Exit Control 179/1125 secures the door handle; the door can be accessed in an emergency with a single opening movement. By pressing down the door handle, the GfS Exit Control 179/1125 moves vertically downwards and frees the handle. At the same time, a continuous signal sounds. The continuous alarm can only be deactivated with the help of a key, and the door guard can be reset to its original position. For continuous passage operation, the permanent release of the system is possible with the device key. The individual passage of the door can also be carried out without triggering an alarm using the key via the change function of the door lock. This means: The door can be opened with just one motion in case of danger, but the alarm signal alerts to unauthorized use. The threshold under the door handle is active.In an emergency, the door can be openedwith one motion. When pressing down the door handle,the Exit Control 179/1125 automatically moves down. Theemergency exit door can now be accessed. Acontinuous alarm sounds, which can only be deactivatedby an authorized person using the device key. Authorized persons do not use the handle,but open the lock latch with the key,to access the door without triggering an alarm. With the device key, the door guard can bemoved down to a permanent release positionwithout an alarm. In this position, the door can benormally accessed, e.g., for a longer goods transport. As soon as the door handle presses down the pre-alarm,an alarm is triggered. Releasing the handlesilences the alarm again. However, if the userpresses the handle all the way down, itirreversibly triggers the main alarm and thedoor guard releases the handle. The basic functions of the EH-RadioDoor Guard are the same as already described.It is used when the signal needs to be forwarded to an externalalarm system, whether at theporter, nurse, or janitor's office.
Show details
Prod.-Nr.: 990100
Variants from €592.86*
€667.83*
Color: RAL 6029 | Modification: no | Pre-alarm: yes | Variants: none | Versions: Base
GfS Exit Control 179/1125 for panic bar with pre-alarm
GFS EH-DOOR GUARD FOR ROD HANDLES In the locked position, the GfS Exit Control 179/1125 secures the rod handle. In case of emergency, the door can be opened in one motion via the panic-bar. By pressing down the rod handle, the GfS Exit Control 179/1125 moves vertically downward, releasing the operating path of the panic-bar. A continuous signal sounds. The door is accessible. The alarm can only be reset with the device key. The deterrent under the door handle is active. In an emergency, the door can be opened with a single motion. When the door handle is pressed down, the Exit Control 179/1125 automaticallymoves downward. The emergency exit door can now be accessed. A continuous alarmsounds, which can only be deactivated by an authorized person using the device key.
Show details
Prod.-Nr.: 994100
Variants from €592.86*
€730.78*
Color: RAL 6029 | Modification: no | Pre-alarm: yes | Variants: none | Versions: panic bar