EMERGENCY AND ESCAPE ROUTES ACCORDING TO DIN EN 179

Here are doors in buildings where the door locks are assumed to be known, e.g., doors in office buildings without public traffic, student dormitories, factories, laboratories, power plants, nursing homes.

When a smaller number of people are involved, panic usually does not occur in hazardous situations. This is generally the case in office buildings, for example. At these doors, normal fittings such as handles and push plates are possible. Through information, training, etc., people can be guided to react rationally in threatening situations and overcome their fear. Knowing the escape options leads to appropriate reactions, from which clear decisions emerge: Which way to choose? Through which door? How to open it?


POSSIBLE APPLICATIONS
  • Student dormitories
  • Power plants
  • Laboratories
  • Nursing homes
  • Small factories
  • Hospital rooms
  • Small offices
  • Small hotels
KEY POINTS AT A GLANCE
  • The user knows the function of the lock or has been instructed.
  • No panic situation can arise.
  • The max. release force is 70 N for handles or 150 N when using a push plate.
  • The products used at the emergency exit are tested together (e.g., by MPA Dortmund).
Skip product gallery
GfS Exit Control 179/1125 Basic RAL 6029
GFS Exit Control The GfS Exit Control 179/1125 secures the emergency exit and allows it to be opened with just one single motion. In the locked position, the GfS Exit Control 179/1125 secures the door handle; the door can be accessed in an emergency with a single opening movement. By pressing down the door handle, the GfS Exit Control 179/1125 moves vertically downwards and frees the handle. At the same time, a continuous signal sounds. The continuous alarm can only be deactivated with the help of a key, and the door guard can be reset to its original position. For continuous passage operation, the permanent release of the system is possible with the device key. The individual passage of the door can also be carried out without triggering an alarm using the key via the change function of the door lock. This means: The door can be opened with just one motion in case of danger, but the alarm signal alerts to unauthorized use. The threshold under the door handle is active.In an emergency, the door can be openedwith one motion. When pressing down the door handle,the Exit Control 179/1125 automatically moves down. Theemergency exit door can now be accessed. Acontinuous alarm sounds, which can only be deactivatedby an authorized person using the device key. Authorized persons do not use the handle,but open the lock latch with the key,to access the door without triggering an alarm. With the device key, the door guard can bemoved down to a permanent release positionwithout an alarm. In this position, the door can benormally accessed, e.g., for a longer goods transport. As soon as the door handle presses down the pre-alarm,an alarm is triggered. Releasing the handlesilences the alarm again. However, if the userpresses the handle all the way down, itirreversibly triggers the main alarm and thedoor guard releases the handle. The basic functions of the EH-RadioDoor Guard are the same as already described.It is used when the signal needs to be forwarded to an externalalarm system, whether at theporter, nurse, or janitor's office.
Show details
Prod.-Nr.: 990000
€592.86*
Color: RAL 6029 | Modification: no | Pre-alarm: no | Variants: none | Versions: Base
GfS Exit Control 179/1125 with pre-alarm, RAL 6029
GFS Exit Control The GfS Exit Control 179/1125 secures the emergency exit and allows it to be opened with just one single motion. In the locked position, the GfS Exit Control 179/1125 secures the door handle; the door can be accessed in an emergency with a single opening movement. By pressing down the door handle, the GfS Exit Control 179/1125 moves vertically downwards and frees the handle. At the same time, a continuous signal sounds. The continuous alarm can only be deactivated with the help of a key, and the door guard can be reset to its original position. For continuous passage operation, the permanent release of the system is possible with the device key. The individual passage of the door can also be carried out without triggering an alarm using the key via the change function of the door lock. This means: The door can be opened with just one motion in case of danger, but the alarm signal alerts to unauthorized use. The threshold under the door handle is active.In an emergency, the door can be openedwith one motion. When pressing down the door handle,the Exit Control 179/1125 automatically moves down. Theemergency exit door can now be accessed. Acontinuous alarm sounds, which can only be deactivatedby an authorized person using the device key. Authorized persons do not use the handle,but open the lock latch with the key,to access the door without triggering an alarm. With the device key, the door guard can bemoved down to a permanent release positionwithout an alarm. In this position, the door can benormally accessed, e.g., for a longer goods transport. As soon as the door handle presses down the pre-alarm,an alarm is triggered. Releasing the handlesilences the alarm again. However, if the userpresses the handle all the way down, itirreversibly triggers the main alarm and thedoor guard releases the handle. The basic functions of the EH-RadioDoor Guard are the same as already described.It is used when the signal needs to be forwarded to an externalalarm system, whether at theporter, nurse, or janitor's office.
Show details
Prod.-Nr.: 990100
Variants from €592.86*
€667.83*
Color: RAL 6029 | Modification: no | Pre-alarm: yes | Variants: none | Versions: Base
GfS Exit Control 179/1125 Basic with Radio
GFS Exit Control The GfS Exit Control 179/1125 secures the emergency exit and allows it to be opened with just one single motion. In the locked position, the GfS Exit Control 179/1125 secures the door handle; the door can be accessed in an emergency with a single opening movement. By pressing down the door handle, the GfS Exit Control 179/1125 moves vertically downwards and frees the handle. At the same time, a continuous signal sounds. The continuous alarm can only be deactivated with the help of a key, and the door guard can be reset to its original position. For continuous passage operation, the permanent release of the system is possible with the device key. The individual passage of the door can also be carried out without triggering an alarm using the key via the change function of the door lock. This means: The door can be opened with just one motion in case of danger, but the alarm signal alerts to unauthorized use. The threshold under the door handle is active.In an emergency, the door can be openedwith one motion. When pressing down the door handle,the Exit Control 179/1125 automatically moves down. Theemergency exit door can now be accessed. Acontinuous alarm sounds, which can only be deactivatedby an authorized person using the device key. Authorized persons do not use the handle,but open the lock latch with the key,to access the door without triggering an alarm. With the device key, the door guard can bemoved down to a permanent release positionwithout an alarm. In this position, the door can benormally accessed, e.g., for a longer goods transport. As soon as the door handle presses down the pre-alarm,an alarm is triggered. Releasing the handlesilences the alarm again. However, if the userpresses the handle all the way down, itirreversibly triggers the main alarm and thedoor guard releases the handle. The basic functions of the EH-RadioDoor Guard are the same as already described.It is used when the signal needs to be forwarded to an externalalarm system, whether at theporter, nurse, or janitor's office.
Show details
Prod.-Nr.: 990040
Variants from €592.86*
€801.35*
Color: RAL 6029 | Modification: no | Pre-alarm: no | Variants: Wireless Relay | Versions: Base
GfS Exit Control Window PLUS, with profile half-cylinder flexible right/left, external power supply terminal, RAL 6029
The GfS Exit Control Window - One Device for All Windows Variant: GfS Exit Control Window PLUSEmergency exits in escape routes must always be free and easily accessible for everyone without any tools. This also applies to secondary escape routes. To prevent unauthorized use of these exits, they should be secured. For many years, the variants of the GfS Door Guard family have proven effective for this purpose. Often, the secondary escape route leads through a window or a patio door to the outside. To ensure that no one enters or exits unauthorized, grants access to others, or endangers children, these emergency exits must also be secured. The SolutionEmergency exits in escape routes must always be free and easily accessible for everyone without any tools. This also applies to secondary escape routes. To prevent unauthorized use of these exits, they should be secured. For many years, the variants of the GfS Door Guard family have proven effective for this purpose. Often, the secondary escape route leads through a window or a patio door to the outside. To ensure that no one enters or exits unauthorized, grants access to others, or endangers children, these emergency exits must also be secured. • NEW flexible strike angle optimizes planning: One device for all windows• Easy installation on common window models• Ideal for retrofitting• No electrical installation required as it is battery-operated• Pictograms included• Approx. 95 dB/1 m• Permanent open function• In compliance with DIN EN 179• High deterrent against misuse• Durable due to robust metal housing• Adhesive plate optional for easy, drill-free installation The handle is secured by the GfS Exit Control Window.However, the window can still be opened in an emergencywith a single opening movement by turning thehandle. By turning the window handle, the GfSExit Control Window is activated. An alarm sounds,which can only be reset with the device key. The GfS Exit Control Window can be set to permanent openby turning the device key 180 degrees.This allows the window to be opened without an alarm,for example, for ventilation.
Show details
Prod.-Nr.: 915110
€523.60*
Tip
GfS Exit Control Window PRAXIS, with profile half-cylinder flexible right/left, battery monitoring, RAL 6029
The GfS Exit Control Window - One Device for All Windows Variant: GfS Exit Control Window PRAXISEmergency exits in escape routes must always be free and easily accessible for everyone without any tools. This also applies to secondary escape routes. To prevent unauthorized use of these exits, they should be secured. For many years, the variants of the GfS Door Guard family have proven themselves for this purpose. Often, the secondary escape route leads through a window or a patio door to the outside. To ensure that no one enters or exits unauthorized, grants access to others, or endangers children, these emergency exits must also be secured. The SolutionEmergency exits in escape routes must always be free and easily accessible for everyone without any tools. This also applies to secondary escape routes. To prevent unauthorized use of these exits, they should be secured. For many years, the variants of the GfS Door Guard family have proven themselves for this purpose. Often, the secondary escape route leads through a window or a patio door to the outside. To ensure that no one enters or exits unauthorized, grants access to others, or endangers children, these emergency exits must also be secured. • NEW flexible strike angle optimizes planning: One device for all windows• Easy installation on common window models• Ideal for retrofitting• No electrical installation required as it is battery-operated• Pictograms included• Approx. 95 dB/1 m• Permanent open function• In compliance with DIN EN 179• High deterrent against misuse• Durable due to robust metal housing• Adhesive plate optional for easy, drill-free installation The handle is secured by the GfS Exit Control Window.However, the window can still be opened in an emergencywith a single opening movement by turning thehandle. By turning the window handle, the GfSExit Control Window is activated. An alarm sounds,which can only be reset with the device key. The GfS Exit Control Window can be set to permanent openby turning the device key 180 degrees.This allows the window to be opened without an alarm,for example, for ventilation.
Show details
Prod.-Nr.: 915100
€487.42*